NVME-CONNECT-ALL(1) | NVMe Manual | NVME-CONNECT-ALL(1) |
NAME¶
nvme-connect-all - Discover and Connect to Fabrics controllers.
SYNOPSIS¶
nvme connect-all
[--transport=<trtype> | -t <trtype>]
[--traddr=<traddr> | -a <traddr>]
[--trsvcid=<trsvcid> | -s <trsvcid>]
[--host-traddr=<traddr> | -w <traddr>]
[--hostnqn=<hostnqn> | -q <hostnqn>]
[--hostid=<hostid> | -I <hostid>]
[--raw=<filename> | -r <filename>]
[--keep-alive-tmo=<#> | -k <#>]
[--reconnect-delay=<#> | -c <#>]
[--ctrl-loss-tmo=<#> | -l <#>]
[--hdr_digest | -g]
[--data_digest | -G]
[--nr-io-queues=<#> | -i <#>]
[--nr-write-queues=<#> | -W <#>]
[--nr-poll-queues=<#> | -P <#>]
[--queue-size=<#> | -Q <#>]
DESCRIPTION¶
Send one or more Discovery requests to a NVMe over Fabrics Discovery Controller, and create controllers for the returned discovery records.
If no parameters are given, then nvme connect-all will attempt to find a /etc/nvme/discovery.conf file to use to supply a list of connect-all commands to run. If no /etc/nvme/discovery.conf file exists, the command will quit with an error.
Otherwise a specific Discovery Controller should be specified using the --transport, --traddr and if necessary the --trsvcid and a Diѕcovery request will be sent to the specified Discovery Controller.
See the documentation for the nvme-discover(1) command for further background.
OPTIONS¶
-t <trtype>, --transport=<trtype>
Value | Definition |
rdma | The network fabric is an rdma network (RoCE, iWARP, Infiniband, basic rdma, etc) |
fc | WIP The network fabric is a Fibre Channel network. |
loop | Connect to a NVMe over Fabrics target on the local host |
-a <traddr>, --traddr=<traddr>
-s <trsvcid>, --trsvcid=<trsvcid>
-w <traddr>, --host-traddr=<traddr>
-q <hostnqn>, --hostnqn=<hostnqn>
-I <hostid>, --hostid=<hostid>
-r <filename>, --raw=<filename>
-k <#>, --keep-alive-tmo=<#>
-c <#>, --reconnect-delay=<#>
-l <#>, --ctrl-loss-tmo=<#>
-g, --hdr_digest
-G, --data_digest
-i <#>, --nr-io-queues=<#>
-W <#>, --nr-write-queues=<#>
-P <#>, --nr-poll-queues=<#>
-Q <#>, --queue-size=<#>
EXAMPLES¶
# nvme connect-all --transport=rdma --traddr=192.168.1.3 \ --hostnqn=host1-rogue-nqn
# Machine default 'nvme discover' commands. Query the # Discovery Controller's two ports (some resources may only # be accessible on a single port). Note an official # nqn (Host) name defined in the NVMe specification is being used # in this example. -t rdma -a 192.168.69.33 -s 4420 -q nqn.2014-08.com.example:nvme:nvm-subsystem-sn-d78432 -t rdma -a 192.168.1.4 -s 4420 -q nqn.2014-08.com.example:nvme:nvm-subsystem-sn-d78432 At the prompt type "nvme connect-all".
SEE ALSO¶
NVME¶
Part of the nvme-user suite
04/15/2019 | NVMe |